TECHNICAL SPECIFICATIONS
Thermal Integrity Profiler with TAG and TAP-Edge Specifications
21-182
PDF Format
Main Unit
Physical
Size: 272 x 212 x 60 mm (10.7 in x 8.3 in x 2.4 in)
Weight: 2.04 Kg (4.5 lbs.)
Sunlight readable VGA color display for any lighting conditions, resolution 640 pixels x 480 pixels
Screen size: 21.3 cm (8.4 in)
Temperature Range: Operating: -20º to 40º C (-4º to 104 º F); Storage: -30º to 65º C (-22º to 149º F)
Powered by Internal Battery (10-hour duration)
Data Storage: Built in 32 GB drive minimum
Data Retrieval: USB port or WiFi
Microsoft Windows® 10 Operating System
Thermal Acquisition Port for Wires (TAP)
Size: 133 x 102 x 57 mm (5.2 x 4 x 2.2 in)
Weight: 766 g (1.7 lbs.)
Temperature Range: Operating: -20° to 65° C (-4º to 149º F); Storage -40° to 85° C (-40º to 185º F)
Contains 1 installed Li-Ion battery or 0.64 grams ELC
Internal Battery (28-day duration)
Sampling frequency: user programmable, defaulted to once every 15 minutes
Hangs from reinforcement cage; may be bolted to cage for security
Water Resistant
Thermal Acquisition Port with cloud access for Wires (TAP-Edge)
Size: 114 x 65 x 41 mm (4.5 x 2.6 x 1.6 in)
Weight: 400 g (0.9 lbs.)
Temperature Range: Operating -20° to 65° C (-4º to 149º F); Storage -40° to 85° C (-40º to 185º F)
Contains 2 installed Li-Ion battery (14.8 W Hrs.)
Internal Battery (20-day duration)
Sampling frequency: user programmable, defaulted to once every 15 minutes
Hangs from reinforcement cage; may be bolted to cage for security
Water Resistant
Thermal Aggregator for Wires (TAG)
Size: 160 x 80 x 57 mm (6.3 x 3.2 x 2.2 in)
Weight: 640 g (1.4 lbs.)
Temperature Range: Operating: -20° to 65° C (-4º to 149º F); Storage -40° to 85° C (-40º to 185º F)
Contains 2 installed Li-Ion battery (22.2 W Hrs.)
Internal Battery (10-day duration)
Sampling frequency: user programmable, defaulted to once every 15 minutes
Hangs from reinforcement cage; may be bolted to cage for security
Water Resistant
Thermal Wire Tester Box for Wires
Size: 133 x 102 x 57 mm (5.2 x 4 x 2.2 in)
Weight: 766 g (1.7 lbs.)
Temperature Range: Operating: -20° to 65° C (-4º to 149º F); Storage -40° to 85° C (-40º to 185º F)
Contains 1 installed Li-Ion battery or 0.64 grams ELC
Internal Battery (28-day duration)
LCD Display Screen
Adapter cable included for splice cables and is required for spliced cables
Does not store data
Thermal Wire® Cables
Sensor type: digital, NIST traceable
Furnished in rolls of length starting at 6 m (20 ft) with length increments of 1.5 m (5 ft)
Sensor spacing: 305 mm (12 in)
Sensor operating temperature: -20° to 65° C (-4º to 149º F)
Sensor Accuracy: ± 0.5º C (± 0.9° F)
Splicing: multi segment cables available upon request – featuring quick-connect
Thermal Acquisition Port for Probes (TAPP)
Size: 114 x 133 x 57 mm (4.5 x 5.2 x 2.2 in)
Weight: 822 g (1.8 lbs.)
Temperature Range: Operating: -20° to 65° C (-4º to 149º F); Storage -40° to 85° C (-40º to 185º F)
Internal Battery (8-hour duration)
Contains 2 installed Li-Ion batteries (1.28 grams ELC)
Sampling frequency: once per second, or as a function of depth (user adjustable)
Water Resistant
Probe
Sensor type: infrared (four orthogonal sensors)
Size: 130 x 30 mm (5.1 x 1.2 in)
Weight (Probe): 5.2 kg (11.5 lbs.)
Cable length: 60 or 100 m (200 or 332 ft)
Weight (60 m Cable): 3.3 kg (7.4 lbs.)
Weight (100 m Cable): 8 kg (17.6 lbs.)
Sensor operating temperature: up to 105° C (221º F)
Removable sensor head
Water resistant
Depth Measurement Unit
Type: Rotary Encoder
Resolution: 2.5 mm (0.1 in)
Other
Soft carrying case
Full one-year warranty
Operates in English or Metric units
Technical manual provided in PDF form on a USB drive